Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Commun Biol ; 7(1): 384, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553561

RESUMO

Humans receive sensory information from the past, requiring the brain to overcome delays to perform daily motor skills such as standing upright. Because delays vary throughout the body and change over a lifetime, it would be advantageous to generalize learned control policies of balancing with delays across contexts. However, not all forms of learning generalize. Here, we use a robotic simulator to impose delays into human balance. When delays are imposed in one direction of standing, participants are initially unstable but relearn to balance by reducing the variability of their motor actions and transfer balance improvements to untrained directions. Upon returning to normal standing, aftereffects from learning are observed as small oscillations in control, yet they do not destabilize balance. Remarkably, when participants train to balance with delays using their hand, learning transfers to standing with the legs. Our findings establish that humans use experience to broadly update their neural control to balance with delays.


Assuntos
Aprendizagem , Perna (Membro) , Humanos , Mãos , Encéfalo
2.
Med Eng Phys ; 108: 103876, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36195370

RESUMO

Wearable human activity recognition systems (HAR) using inertial measurement units (IMU) play a key role in the development of smart rehabilitation systems. Training of a HAR system with patient data is costly, time-consuming, and difficult for the patients. This study proposes a new scheme for the optimal design of HARs with minimal involvement of the patients. It uses healthy subject data for optimal design for a set of activities used in the rehabilitation of PD1 patients. It maintains its performance for individual PD subjects using a single session data collection and an adaptation procedure. In the optimal design, several classifiers (i.e. NM, k-NN, MLP with RBF as a hidden layer, and multistage RBF SVM) were investigated. Features were signal-based in the time, frequency, and time-frequency domains. Double-stage feature extraction by PCA and fisher technique was used. The optimal design reached a recall of 95% on healthy subjects using only two sensors on the left thigh and forearm. Implementing the adaptation procedure on two PD subjects, the performance was maintained above 80%. Post analysis on the performance of the adapted HAR showed a slight drop in precision (above 87% to above 81%) for activities that was performed in sitting condition.


Assuntos
Telerreabilitação , Dispositivos Eletrônicos Vestíveis , Algoritmos , Atividades Humanas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...